Multi-Pulse Current Fault Tester — A10 (Advanced)
Multi-Pulse Current Fault Tester — A10 (Advanced)
Couldn't load pickup availability
The A10 Advanced Multi-Pulse Current Fault Tester locates intermittent and high-resistance cable faults with ±0.2 m pinpoint accuracy, capturing 10 waveforms per discharge — factory direct at $3,800.
What Is the A10 Advanced Multi-Pulse Fault Tester?
The A10 Advanced is a TDR and multi-pulse generator in one instrument, covering low-voltage pulse, HV impulse flash, and multi-pulse methods up to 40 kV. It captures 10 measured waveforms simultaneously per discharge and auto-selects the optimal one. Built-in WiFi and SIM enable remote waveform transmission to support engineers.
Why Does Multi-Pulse Outperform Single-Shot Testing?
Fault flashover is probabilistic — a single discharge has limited chance of triggering breakdown on intermittent faults. The A10 Advanced fires controlled sequences and captures 10 short-circuit pulse waveforms per event, boosting flashover probability toward 97% over a 10-impulse sequence. Real-time distance tracking confirms the reading converges as the fault stabilizes.
What Are the A10 Advanced's Key Specifications?
The A10 Advanced measures distances from 5 m to 100 km with ±0.2 m pinpoint accuracy and a 5 m blind zone. Its 12.1-inch industrial LCD with 32 GB storage displays waveform history. Multi-pulse generator output reaches 40 kV, and standby time exceeds 6 hours on AC220V/DC12V power.
How Does the A10 Advanced Compare to a Standard TDR?
A standard TDR like the A10 locates low-resistance faults but misses intermittent and high-resistance faults. The A10 Advanced adds integrated multi-pulse conditioning and 10-waveform analysis — the same capability as a separate TDR plus impulse generator. At $3,800, it replaces two tools with one unit.
Key Features
- Ten measured waveforms displayed simultaneously for selection and analysis
- Ten LV short-circuit pulse waveforms from one discharge; auto-select optimal
- Real-time display of distance change between test point and fault point
- Cable path direction detection; WiFi + SIM remote data transmission
Technical Specifications
| Display | 12.1-inch industrial LCD, 32 GB storage |
| Methods | LV pulse, HV impulse flash, multi-pulse |
| Range | 5 m – 100 km (blind zone 5 m) |
| Pinpoint Accuracy | ±0.2 m |
| Multi-Pulse Output | ≤ 40 kV |
| Remote | WiFi + SIM |
| Standby | ≥ 6 hours |
| Power | AC220V ±10% / DC12V |
Applicable Scenarios
- Medium-voltage distribution networks — pre-locate faults on 10–35 kV feeders
- Long rural feeders — reach faults beyond basic TDR range
- Dense urban underground cable systems — pinpoint in congested networks
- Emergency restoration after storms — rapid multi-pulse fault location
- GIS and cross-bonded systems — test complex cable configurations
- High-resistance and intermittent faults — locate faults single shots miss
Testing Method
- Safety check & isolation — de-energize and ground both ends
- Connect test leads — attach TDR/impulse leads to the faulted phase
- Low-voltage pulse pre-location — obtain a first distance reading
- Multi-pulse discharge — apply ≤40 kV sequences for stable flashover
- Review 10 waveforms — select the optimal one (or auto-select)
- Track real-time distance — monitor convergence during discharge
- Confirm direction — verify cable route orientation
- Record & transmit — save to 32 GB; share via WiFi/SIM if needed
- Pinpoint on site — mark the dig point (±0.2 m)
- Discharge & secure — auto-discharge, verify zero voltage
Quality & Delivery
- 100% factory tested — calibration and test certificate included
- CE certified — EU compliance
- Export packaging — foam-lined transit case
- Lead time — 15–20 days
- After-sales — 1-year warranty, lifetime maintenance, free training
FAQ
What is a multi-pulse current fault tester?
A combined TDR and multi-pulse generator that locates intermittent and high-resistance faults a standard TDR misses.
How accurate is the A10 Advanced?
It achieves ±0.2 m pinpoint accuracy with a 5 m–100 km range and 5 m blind zone.
How does multi-pulse improve fault detection?
Repeated impulses raise flashover probability from ~30% per shot toward 97% over 10 impulses.
Can the A10 Advanced be operated remotely?
Yes — built-in WiFi and SIM transmit waveforms to support engineers for remote analysis.
How does it compare to the standard A10 TDR?
The A10 Advanced ($3,800) adds integrated multi-pulse conditioning, replacing a separate impulse generator.