Technical Resources

How to Interpret Partial Discharge Test Results: Magnitude, Patterns and Pass/Fail

How to Interpret Partial Discharge Test Results...

Reading a PD test result comes down to four questions, in this order: 1) Is it PD at all? (pattern, not just magnitude) 2) Where is it? (cable body, joint,...

How to Interpret Partial Discharge Test Results...

Reading a PD test result comes down to four questions, in this order: 1) Is it PD at all? (pattern, not just magnitude) 2) Where is it? (cable body, joint,...

PD Testing Equipment for Commissioning: Building the Right Test Kit

PD Testing Equipment for Commissioning: Buildin...

Commissioning PD testing needs four functional blocks: a VLF excitation source, a calibrated PD measurement unit, a coupling capacitor / PD coupler, and a PD calibrator. Everything else — sensors, noise gating, PD mapping...

PD Testing Equipment for Commissioning: Buildin...

Commissioning PD testing needs four functional blocks: a VLF excitation source, a calibrated PD measurement unit, a coupling capacitor / PD coupler, and a PD calibrator. Everything else — sensors, noise gating, PD mapping...

Common Mistakes in On-Site PD Testing: 10 Errors That Produce False Results

Common Mistakes in On-Site PD Testing: 10 Error...

Most on-site partial discharge (PD) testing errors fall into three groups: measurement circuit errors (no calibration, poor grounding), noise errors (external interference mistaken for PD), and interpretation errors (single readings without trend, wrong test voltage, no...

Common Mistakes in On-Site PD Testing: 10 Error...

Most on-site partial discharge (PD) testing errors fall into three groups: measurement circuit errors (no calibration, poor grounding), noise errors (external interference mistaken for PD), and interpretation errors (single readings without trend, wrong test voltage, no...

High-Resistance Cable Faults: The Complete Field Procedure from Detection to Dig Point

High-Resistance Cable Faults: The Complete Fiel...

High-resistance faults are invisible to a standard TDR, so the field procedure follows a strict sequence: 1) identify the fault type by insulation testing, 2) pre-locate with a bridge method (non-destructive),...

High-Resistance Cable Faults: The Complete Fiel...

High-resistance faults are invisible to a standard TDR, so the field procedure follows a strict sequence: 1) identify the fault type by insulation testing, 2) pre-locate with a bridge method (non-destructive),...

Partial Discharge vs Tan Delta: Which Cable Diagnostic Do You Need?

Partial Discharge vs Tan Delta: Which Cable Dia...

Partial discharge (PD) testing and tan delta (dissipation factor) testing answer different questions. PD finds active defect sites — "is something discharging right now?" Tan delta measures overall insulation condition —...

Partial Discharge vs Tan Delta: Which Cable Dia...

Partial discharge (PD) testing and tan delta (dissipation factor) testing answer different questions. PD finds active defect sites — "is something discharging right now?" Tan delta measures overall insulation condition —...

Cable Commissioning Tests: The Complete Pre-Energization Checklist

Cable Commissioning Tests: The Complete Pre-Ene...

A new cable is only as good as its commissioning record. The complete pre-energization sequence is: visual inspection → insulation resistance (megger) → sheath/jacket test → VLF withstand → partial discharge...

Cable Commissioning Tests: The Complete Pre-Ene...

A new cable is only as good as its commissioning record. The complete pre-energization sequence is: visual inspection → insulation resistance (megger) → sheath/jacket test → VLF withstand → partial discharge...